THE COURSE / M12 THE FAB AS A SYSTEM / M12.2
The cleanroom
After this lesson you can:
- Read a cleanroom class, and say what it limits.
- Explain how downflow, air changes and pressure keep a cleanroom clean.
- Say why people are the main source of particles, and gown in the right order.
Loading the lesson…
Sources
- American Cleanroom Systems, "Cleanroom Classifications (ISO 8, ISO 7, ISO 6, ISO 5)" (read 26 October 2026). ISO 14644-1 limits per m³: ISO 1, 10 particles of 0.1 µm or more; ISO 3, 1,000 (35 of 0.5 µm); ISO 5, 100,000 (3,520 of 0.5 µm); ISO 7, 352,000 of 0.5 µm; ISO 9, 35,200,000 of 0.5 µm. FED-STD-209E Class 1, 10, 100 match ISO 3, 4, 5. Design air changes: ISO 4, 500–600 an hour with 90–100% of the ceiling filtered; ISO 5, 300–480 with 60–70%; ISO 7, 60 with 7–15%.
- American Cleanroom Systems, "Cleanroom Gowning Procedure: The Correct Order, Step by Step" (read 26 October 2026). A person sheds about 40,000 skin cells a minute; walking across a room can throw off more than a million particles a minute; personnel account for an estimated 75–80% of the particles in a cleanroom. Gowning covers what sheds; the rule is top to bottom, clean to dirty, and never let a garment touch the floor; air showers blow off loose particles before entry.
- CKY Refrigeration & Air Conditioning Engineering Office, "Semiconductor Fab HVAC Design" (14 November 2025). Typical classes by area: lithography and etch ISO 1 to 3, CMP and implant ISO 4 to 5, back-end packaging and test ISO 6 to 7; EUV local environments may need ISO 1. Fan filter coverage 60–80% for ISO 5, 80–100% with ULPA filters for ISO 3 and cleaner. Lithography at 23 ± 0.1 °C, where a 0.1 °C deviation can shift overlay by several nanometres; humidity 45 ± 2%. Make-up air units bring outdoor air down to a 10–12 °C dew point; dry cooling coils in the return air; chilled water at 6–7 °C and 15–18 °C; toxic exhaust ducts at 12–15 m/s; lithography floors to vibration class VC-D or VC-E.
- ACH Engineering, "What is Differential Pressure?" (2024, updated 2026). Cleaner areas are kept at higher pressure so particles can't enter from dirtier ones; air moves from high pressure to low; 10–15 Pa is typical between spaces of different classes; through an open doorway the outward airflow should stay above about 0.2 m/s.
- H. Hogan, "300mm theory and practice," Solid State Technology (2000). Sealed front-opening unified pods (FOUPs) of 25 wafers, moved by automated material handling; all 300 mm tools have minienvironments, pressurized at least +0.003 in w.c. above the room or contaminants get in; a typical cleanroom ISO 3 to 7; minienvironments let fabs run a less clean room.