THE COURSE / M12 THE FAB AS A SYSTEM / M12.2

The cleanroom

After this lesson you can:

  • Read a cleanroom class, and say what it limits.
  • Explain how downflow, air changes and pressure keep a cleanroom clean.
  • Say why people are the main source of particles, and gown in the right order.

Loading the lesson…

Sources

  1. American Cleanroom Systems, "Cleanroom Classifications (ISO 8, ISO 7, ISO 6, ISO 5)" (read 26 October 2026). ISO 14644-1 limits per m³: ISO 1, 10 particles of 0.1 µm or more; ISO 3, 1,000 (35 of 0.5 µm); ISO 5, 100,000 (3,520 of 0.5 µm); ISO 7, 352,000 of 0.5 µm; ISO 9, 35,200,000 of 0.5 µm. FED-STD-209E Class 1, 10, 100 match ISO 3, 4, 5. Design air changes: ISO 4, 500–600 an hour with 90–100% of the ceiling filtered; ISO 5, 300–480 with 60–70%; ISO 7, 60 with 7–15%.
  2. American Cleanroom Systems, "Cleanroom Gowning Procedure: The Correct Order, Step by Step" (read 26 October 2026). A person sheds about 40,000 skin cells a minute; walking across a room can throw off more than a million particles a minute; personnel account for an estimated 75–80% of the particles in a cleanroom. Gowning covers what sheds; the rule is top to bottom, clean to dirty, and never let a garment touch the floor; air showers blow off loose particles before entry.
  3. CKY Refrigeration & Air Conditioning Engineering Office, "Semiconductor Fab HVAC Design" (14 November 2025). Typical classes by area: lithography and etch ISO 1 to 3, CMP and implant ISO 4 to 5, back-end packaging and test ISO 6 to 7; EUV local environments may need ISO 1. Fan filter coverage 60–80% for ISO 5, 80–100% with ULPA filters for ISO 3 and cleaner. Lithography at 23 ± 0.1 °C, where a 0.1 °C deviation can shift overlay by several nanometres; humidity 45 ± 2%. Make-up air units bring outdoor air down to a 10–12 °C dew point; dry cooling coils in the return air; chilled water at 6–7 °C and 15–18 °C; toxic exhaust ducts at 12–15 m/s; lithography floors to vibration class VC-D or VC-E.
  4. ACH Engineering, "What is Differential Pressure?" (2024, updated 2026). Cleaner areas are kept at higher pressure so particles can't enter from dirtier ones; air moves from high pressure to low; 10–15 Pa is typical between spaces of different classes; through an open doorway the outward airflow should stay above about 0.2 m/s.
  5. H. Hogan, "300mm theory and practice," Solid State Technology (2000). Sealed front-opening unified pods (FOUPs) of 25 wafers, moved by automated material handling; all 300 mm tools have minienvironments, pressurized at least +0.003 in w.c. above the room or contaminants get in; a typical cleanroom ISO 3 to 7; minienvironments let fabs run a less clean room.