THE COURSE / M12 THE FAB AS A SYSTEM / M12.3
Utilities
After this lesson you can:
- Name what every tool is fed, and what is taken away from it.
- Say what makes water ultrapure, and follow it through the plant that makes it.
- Explain how a tool's hazardous exhaust is treated before it leaves the building.
Loading the lesson…
Sources
- Kuehne+Nagel, "Sub-fabs: The unsung heroes of semiconductor manufacturing" (2026). Sub-fabs sit beneath or beside cleanrooms to isolate heat, noise and contaminants; every tool has a footprint below: gas lines, vacuum pumps, abatement, power conditioning and cooling. Bulk and specialty gases through gas cabinets, gas sticks and manifolds; resists, developers, solvents, CMP slurries and etchants stored and blended there; uninterruptible supplies, since a voltage transient can damage a tool or a wafer in flight. Process exhaust carries pyrophoric and toxic byproducts and fluorinated greenhouse gases (PFCs, NF3, SF6) thousands of times as potent as CO2, captured and neutralised before it leaves, by point-of-use, sub-fab and stack treatment in layers. An advanced fab can use two to four million gallons of ultrapure water a day, above 18.2 MΩ·cm with trace contaminants in parts per trillion.
- MKS Instruments, "Ultrapure Water for Semiconductor Manufacturing" (read 26 October 2026). Resistivity's theoretical limit for water with no ions is 18.25 MΩ·cm (ITRS 2015: above 18.0 at 25 °C); organic carbon under 1 ppb, driven by immersion lithography, where carbon hazes the lens; dissolved oxygen under 5 ppb; particles above 0.2 µm not tolerated (ITRS: under 0.3 per ml at 0.05 µm); metals and ions 0.02–1 ppb. Reverse osmosis and ion exchange at the base, finer filters and ultrafiltration, UV and degassing for organic carbon, vacuum degassing in membrane contactors for oxygen. A 200 mm fab of 20,000 wafers a month can use up to 3,000 m³ of UPW a day, the water of about 20,000 people; ITRS put use at 7 litres per cm² of wafer out (2011).
- CKY Refrigeration & Air Conditioning Engineering Office, "Semiconductor Fab HVAC Design" (14 November 2025). Typical classes by area: lithography and etch ISO 1 to 3, CMP and implant ISO 4 to 5, back-end packaging and test ISO 6 to 7; EUV local environments may need ISO 1. Fan filter coverage 60–80% for ISO 5, 80–100% with ULPA filters for ISO 3 and cleaner. Lithography at 23 ± 0.1 °C, where a 0.1 °C deviation can shift overlay by several nanometres; humidity 45 ± 2%. Make-up air units bring outdoor air down to a 10–12 °C dew point; dry cooling coils in the return air; chilled water at 6–7 °C and 15–18 °C; toxic exhaust ducts at 12–15 m/s; lithography floors to vibration class VC-D or VC-E.