THE COURSE / M12 THE FAB AS A SYSTEM / M12.5

Safety

After this lesson you can:

  • Name the fab's three kinds of chemical hazard, with an example of each.
  • Explain how hazardous gases are kept in a closed, watched path, and what happens when one leaks.
  • Say what to do when an alarm sounds, and when hydrofluoric acid touches skin.

Loading the lesson…

Sources

  1. NIOSH Pocket Guide to Chemical Hazards, "Silicon tetrahydride" (silane) (read 26 October 2026). Colourless gas with a repulsive odour; flammable, may ignite spontaneously in air. REL 5 ppm (8-hour); no OSHA PEL; IDLH not determined.
  2. NIOSH Pocket Guide to Chemical Hazards, "Arsine" (read 26 October 2026). Colourless gas, mild garlic-like odour, shipped as a liquefied compressed gas. REL: carcinogen, ceiling 0.002 mg/m³ (15 minutes); OSHA PEL 0.05 ppm; IDLH 3 ppm. Targets blood, kidneys, liver; potential occupational carcinogen.
  3. NIOSH Pocket Guide to Chemical Hazards, "Phosphine" (read 26 October 2026). Colourless flammable gas, may ignite spontaneously on contact with air. REL 0.3 ppm (8-hour), short-term 1 ppm; IDLH 50 ppm. Symptoms include chest tightness, breathing difficulty, pulmonary oedema.
  4. NIOSH Pocket Guide to Chemical Hazards, "Hydrogen fluoride" (read 26 October 2026). Gas, or fuming liquid below 67 °F; hydrofluoric acid in solution. REL 3 ppm (8-hour), ceiling 6 ppm; IDLH 30 ppm. Burns eyes and skin; targets eyes, skin, respiratory system, bones. First aid: flush skin with water immediately.
  5. USC John O'Brien Nanofabrication Facility, "Standard operating procedure for emergency responses" (2021). Gases kept in a closed system: gas cabinets exhausted to scrubbers, valve manifold boxes, the tools' piping, dedicated exhaust to scrubbing. A toxic gas monitoring system detects gas releases, loss of exhaust and loss of power and responds: shuts gas off at the cabinets and VMBs, alarms the building and a 24-hour monitored panel. Detectors on each cabinet's and VMB's exhaust, the scrubber outlet and each tool. Low alarm (leak in an enclosure: cabinet, tool, VMB) evacuates the cleanroom; high alarm (leak perhaps outside an enclosure) the building. Evacuate at once; take off gowns at the safe area; meet at the assembly point. An uncontrolled release is vented through its cabinet to the scrubber; responders monitor the air.
  6. UCSB Nanofabrication Facility, "Policy, guidelines and chemical hygiene plan" (2012). Fire alarm: leave by the nearest exit; do not remove the bunny suit until outside. Toxic gas alarm (blue strobes at each bay's ends): in one bay, do not enter it; throughout, leave by the nearest exit. HF only at the HF benches, always with a face shield, acid apron and chemical gloves. HF on skin: rinse at the safety shower for 5 minutes, then massage in 2.5% calcium gluconate gel and seek medical attention at once.
  7. OSHA, Evacuation Plans and Procedures eTool, "Emergency action plan: elements" (read 26 October 2026). Maps with exits and assembly points; exit routes marked, lit, wide enough, clear, and unlikely to expose evacuees to more hazards; who stays to shut down critical operations; a means of accounting for employees after an evacuation; evacuation wardens, about one for every 20 employees, checking spaces before leaving last.
  8. Kuehne+Nagel, "Sub-fabs: The unsung heroes of semiconductor manufacturing" (2026). Sub-fabs sit beneath or beside cleanrooms to isolate heat, noise and contaminants; every tool has a footprint below: gas lines, vacuum pumps, abatement, power conditioning and cooling. Bulk and specialty gases through gas cabinets, gas sticks and manifolds; resists, developers, solvents, CMP slurries and etchants stored and blended there; uninterruptible supplies, since a voltage transient can damage a tool or a wafer in flight. Process exhaust carries pyrophoric and toxic byproducts and fluorinated greenhouse gases (PFCs, NF3, SF6) thousands of times as potent as CO2, captured and neutralised before it leaves, by point-of-use, sub-fab and stack treatment in layers. An advanced fab can use two to four million gallons of ultrapure water a day, above 18.2 MΩ·cm with trace contaminants in parts per trillion.