Skip to content

THE COURSE / M4 PATTERNING / M4.4

DUV immersion

After this lesson you can:

  • Explain how water under the lens lifts the numerical aperture above 1, and what limits it.
  • Describe step and scan: the reticle and wafer moving through a slit of light, field by field.
  • Say what the scanner measures before it exposes, and how a layer is aligned to the ones below.

Loading the lesson…

Sources

  1. ASML, "Light and lasers," lithography principles (read 26 October 2026). Mercury lamps at 436 and 365 nm; excimer lasers, in which two gases that don't normally combine form excited temporary molecules that release light: krypton fluoride at 248 nm and argon fluoride at 193 nm, which enabled 38 nm features; EUV at 13.5 nm from tin droplets hit by laser pulses 50,000 times a second.
  2. Y. Wei, "Extendability of 193nm immersion lithography," SPIE Newsroom (27 February 2008). Water's refractive index at 193 nm is about 1.44; commercial water-immersion scanners reach NA 1.3 or 1.35 and 45 nm half-pitch. The NA is limited by the refractive index of the lens, the fluid and the resist; fused silica is 1.55 at 193 nm.
  3. S. Hofman, "How immersion lithography saved Moore's Law," ASML (2 August 2023). In 2001 157 nm lithography hit problems; water under the lens extended 193 nm instead, with the same optics, masks and resists. The first immersion system announced in December 2003; volume production in 2006, NA from 0.93 to 1.2; then multi-patterning, where "overlay, rather than imaging resolution, became the critical parameter".
  4. ASML, "Mechanics and mechatronics," lithography principles (read 26 October 2026). The reticle moves through a narrow slit of light, exposing a small part of the pattern at a time, while the wafer moves the other way; the pattern is printed in almost 100 places on a wafer. Reticle and wafer accelerate at 15 g and 5 g in opposite directions; the wafer's position is measured some 20,000 times a second to about 60 picometres.
  5. J. Timings, "TWINSCAN: 20 years of lithography innovation," ASML (18 August 2021). Two wafer tables: while the wafer on one is exposed, the next is loaded on the other, aligned and mapped; then they swap. The first TWINSCAN shipped in 2001; immersion NXT systems now run 295 wafers an hour with overlay down to 1 nm.
  6. ASML, TWINSCAN NXT:2050i (product page, read 26 October 2026). A 1.35 NA, 193 nm catadioptric projection lens, production resolution down to 38 nm with dipole illumination and 40 nm with C-quad; a 26 × 33 mm field at 4× reduction; the ORION alignment sensor; a UV level sensor mapping the wafer in line; a new immersion hood that loses less water, improving defects; 295 wafers an hour; 2.5 nm cross-matched overlay with ASML's EUV systems.