THE COURSE / M7 DOPING AND HEAT / M7.2
Ion implantation
After this lesson you can:
- Follow an ion through an implanter, and say what each part of the beamline does.
- Work out an implant's time from its dose and beam current, and its peak from its dose and straggle.
- Explain channeling, and why implants are tilted.
Loading the lesson…
Sources
- J. D. Plummer, M. D. Deal and P. B. Griffin, "Ion Implantation," EE212 class handout for chapter 8 of Silicon VLSI Technology (Stanford, 1999). Doses of 10¹¹ to 10¹⁶ per cm², counted by the integrated beam current; the beamline; a Gaussian with range Rp and straggle ΔRp, peak = dose ÷ (√(2π)·ΔRp); mask thickness; channeling, eased by a 7° tilt; damage, amorphization, regrowth; transient enhanced diffusion.
- L. Rubin and J. Poate, "Ion Implantation in Silicon Technology," The Industrial Physicist 9(3), 12–15 (American Institute of Physics, 2003). Implantation displaced diffusion for being more precise, reliable and repeatable; dose and energy are set on the tool; up to 35 implants in a CMOS chip; three classes of implanter, high current, medium current and high energy, with their beam currents, energies and uses; tilts up to 60°. Both authors worked at Axcelis.