THE COURSE / M7 DOPING AND HEAT / M7.2

Ion implantation

After this lesson you can:

  • Follow an ion through an implanter, and say what each part of the beamline does.
  • Work out an implant's time from its dose and beam current, and its peak from its dose and straggle.
  • Explain channeling, and why implants are tilted.

Loading the lesson…

Sources

  1. J. D. Plummer, M. D. Deal and P. B. Griffin, "Ion Implantation," EE212 class handout for chapter 8 of Silicon VLSI Technology (Stanford, 1999). Doses of 10¹¹ to 10¹⁶ per cm², counted by the integrated beam current; the beamline; a Gaussian with range Rp and straggle ΔRp, peak = dose ÷ (√(2π)·ΔRp); mask thickness; channeling, eased by a 7° tilt; damage, amorphization, regrowth; transient enhanced diffusion.
  2. L. Rubin and J. Poate, "Ion Implantation in Silicon Technology," The Industrial Physicist 9(3), 12–15 (American Institute of Physics, 2003). Implantation displaced diffusion for being more precise, reliable and repeatable; dose and energy are set on the tool; up to 35 implants in a CMOS chip; three classes of implanter, high current, medium current and high energy, with their beam currents, energies and uses; tilts up to 60°. Both authors worked at Axcelis.