THE COURSE / M8 INTEGRATION / M8.6
Power from the back: the bond
After this lesson you can:
- Explain why power is moving from the front-side wiring to the back of the wafer.
- Say what has to be planned from the start, and why the wafer is bonded to a carrier before anything else.
- Tell fusion bonding from hybrid bonding, and say which the backside route uses.
Loading the lesson…
Sources
- imec, "Imec demonstrates critical building blocks for a backside power delivery network" (10 June 2021). Power delivered from the back: a Si/SiGe stack grown first, its SiGe an etch stop; the front built; the wafer flipped and bonded face down to a carrier; the back thinned to the SiGe, which is removed; tungsten nano-TSVs and backside metal; final silicon 20 to 370 nm thick; it largely reduces the IR drop from rising wiring resistance.
- EV Group, "Hybrid and Fusion Bonding" (technology page, read 25 October 2026). Fusion, or direct, bonding joins dielectric layers on each wafer: activated surfaces pre-bond at room temperature through hydrogen bridge bonds, and an anneal turns them covalent. Hybrid bonding adds metal pads in the interface for face-to-face electrical connection, as in stacked image sensors, memory and 3D systems-on-chip.
- B. W. Ku, P. Debacker, D. Milojevic, P. Raghavan, D. Verkest, A. Thean and S. K. Lim, "Physical design solutions to tackle FEOL/BEOL degradation in gate-level monolithic 3D ICs," ISLPED 2016. With copper wiring below, later processing must stay under 450 °C, or copper diffuses into the low-k insulator.