Skip to content

THE COURSE / M9 MEASURE AND YIELD / M9.2

Film thickness by light

After this lesson you can:

  • Explain how light reflected from a film's top and bottom measures its thickness.
  • Say what the model fit does, and when ellipsometry is needed rather than reflectance alone.
  • Read a thickness map, and name what optical film measurement can't do.

Loading the lesson…

Sources

  1. J. Lee and J. Jin, "A novel method to design and evaluate artificial neural network for thin film thickness measurement traceable to the length standard," Scientific Reports 12, 2212 (2022). Spectral reflectometry: light reflected from a film's top and bottom interferes; each measured spectrum is compared with spectra calculated for a model; certified reference wafers of SiO₂ on Si, certified by spectroscopic ellipsometry at KRISS: nominal 10 nm, certified 13.8 nm, expanded uncertainty 1.2 nm.
  2. L. Liu, W. Shi, S. Xu and X. Wang, "Dispersion Compensation and Multi-Beam Interference Correction Algorithm for Thickness Measurement of SiC Epitaxial Layer," Sensors 26, 2965 (2026). Thin-film interference: the round trip in a layer adds an optical path of 2·n·d·cosθ; reflectance minima where d = (2k + 1)λ / (4n cosθ).
  3. K.-N. Joo and H.-M. Park, "Recent Progress on Optical Tomographic Technology for Measurements and Inspections of Film Structures," Micromachines 13, 1074 (2022). Ellipsometry measures the change in polarization on reflection, Ψ and Δ, and spectroscopic ellipsometry is more reliable; under 10 nm the changes in Ψ become extremely small; reflectometry suits thick or single films and cannot separate thickness and index without prior knowledge; optical methods need transparent films, X-ray and ultrasound suit opaque and metal ones.
  4. N. G. Orji, M. Badaroglu, B. M. Barnes, C. Beitia, B. D. Bunday, U. Celano, R. J. Kline, M. Neisser, Y. Obeng and A. E. Vladár, "Metrology for the next generation of semiconductor devices," Nature Electronics 1, 532–547 (2018), author manuscript. For some products more than half the manufacturing steps can involve measurement; CD-SEM, scatterometry and image-based or scatterometry overlay, CD-SAXS, TEM (destructive), AFM; hybrid metrology; precision and stability matter more than absolute accuracy for most fab uses, traceability when instruments are compared; methods divergence, such as 2.7 nm between CD-AFM and EUV scatterometry; under 5 nm, a deviation under 10% can affect device performance.
  5. J. Oh, J. Son, C. Yoon et al., "Ultra-wide-field imaging Mueller matrix spectroscopic ellipsometry for semiconductor metrology," Nature Communications 16, 8512 (2025). Spectroscopic reflectometry and ellipsometry give thickness and CD non-destructively but point by point, limiting spatial density and throughput; SEM's field of view is small; an imaging instrument measuring over ten million spectra across 20 × 20 mm.